Stabilised Oscillators
CRO & DRO

  • 400 MHz to 18 GHz
  • Fundamental Frequency (CRO or DRO)
  • Small Size
  • Low Phase Noise
  • Low Microphonics
  • Low Current
  • Custom Design

The ACR and ADR series of fundamental frequency stabilised oscillators utilise coaxial resonators (CRO) to 3GHz and dielectric resonators (DRO) to 18 GHz. Circuit design uses SMT devices including Si bipolar active devices up to 3 GHz and GaAs FET active devices above 3 GHz. The output contains a buffer amplifier for improved ruggedness, higher output power and a wider range of load VSWR. DRO types have an external tuning screw for factory set up and limited mechanical tuning.

 General Specifications (also see options)
 Output Frequency (fixed) (see options for tuning) 400 MHz to 18.0 GHz
 Frequency Stability
 400 MHz to 3.0 GHz (CRO)
 3.0 GHz to 14.0 GHz (DRO)

+/-10ppm/degC max.
+/-5ppm/degC max.
 Output Power +13dBm min. (see options)
 Output Power Stability +/-2dB max
 Harmonics -20dBc max.
 Spurious -80dBc max.
 Frequency Pulling +/-1MHz max. @ 1.7:1VSWR
 Frequency Pushing +/-1MHz/V max.
 Input Voltage +15V d.c. (see options)
 Input Current 125mA max. (for +13dBm)
 Mechanical Tuning (DRO only) 1% typ.
 Operating Temperature 0+50C standard (see options)
 Storage Temperature -40+85C

Phase Noise (dBc/Hz) (typical)
Offset Frequency (Hz) Output Frequency (GHz)
0.6 1.5 3.0 4.0 10.0 14.0
1K -95 -85 -75 -75 -70 -65
10K -115 -105 -95 -95 -90 -85
100K -135 -125 -115 -115 -110 -105
1M -140 -140 -135 -135 -120 -115

Options:
00 - Standard
Operating Temperature
01 - -10+60C
02 - -20+70C
03 - -40+85C
Output Power
11 - +16dBm min. up to 10 GHz
12 - +20dBm min. up to 6 GHz
D.C. Supply
21 - Input Voltage +12V d.c.
22 - Regulated +11 to +16 V d.c.
23 - +28V d.c.
Electrical Tuning
31- Electrical Tuning for 0 - 12V
      400 MHz to 3.0 GHz (CRO) 0.5% typ.
      3.0 GHz to 14.0 GHz (DRO) 0.2% typ.

Custom Options:

  • Higher Output Frequency to 30 GHz (multiplied)
  • Higher Output Power to +30dBm (amplified)
  • Lower Harmonics (filtered)
  • Custom Sizes
  • Instrument or Rack Mount Housing with Power Supply

Model Numbers:
Examples:
ACR-1.750-00 1.75 GHz CRO with standard specifications
ADR-9.050-02-11-23 9.05 GHz DRO with -20+70C, +16dBm and +28V.


All dimensions are inches (mm)

We reserve the right to change standard product specifications without notice but will be pleased to consider control drawings for quotation.

T: +44 (0)1376 550220 F: +44 (0)1376 552145 E: sales@atlantecrf.com 40A Springwood Drive, Braintree, Essex CM7 2YN, England